Electrical Feedthroughs
:.........................................................................................
attocube systems offers a large variety of cabling sets and vacuum feedthroughs for low temperature, high vacuum, and ultra high vacuum applications.
 |
| |
| Electrical Feedthrough |
|
Cabling sets to connect attocube positioners into your cryostat or
vacuum chamber |
|
VFT/UHV |
Flange |
CF40 or CF63 flange, with Copper ring gasket, D-Sub feedthroughs, male-male, material: Stainless Steel 316L (1.4404) |
|
UHV components |
woven flat cables, Kapton® coating, length 0.5 m, D-Sub female connector to attach to the feedthrough, D-Sub male connector to attach to the positioners, connector material: PEEK, MACOR® on request |
|
RT components |
adapter cable at ambient pressure, length 2 m, D-Sub female connector to attach to the feedthrough, male D-Sub mix connector to attach to ANC350 |
VFT/HV |
Flange |
KF40 or KF63 flange, D-Sub feedthroughs, male-male, material: Stainless steel 316L (1.4404) |
|
HV components |
woven flat cable, Kapton® coating, length 0.5 m, D-Sub female connector to attach to the feedthrough, D-Sub male connector to attach to the positioners, connector material: PEEK, MACOR® on request |
|
RT components |
adapter cable at ambient pressure, length 2 m, D-Sub female connector to attach to the feedthrough, male D-Sub mix connector to attach to ANC350 |
VFT/LT |
Flange |
LT flange (e.g. KF25 or KF40) with LT compatible feedthroughs, male-male, |
|
LT components |
optional: inside LT compatible cabling |
|
RT components |
adapter cable at ambient pressure, length 2 m, LT compatible female connector to attach to the feedthrough, male D-Sub mix connector to attach to ANC350 |
| Vacuum Feedthrough |
Electronics |
RT Cable |
Flange |
No of Pos. |
| VFT3/KF16/LT |
ANC250, ANC300 |
3 x BNC |
KF16 |
3 Open Loop |
| VFT3/SCN/KF16/LT |
ANC350 |
3 x SCN |
KF16 |
3 Open Loop |
| VFT1/RES/KF16/LT |
ANC350 |
1 x RES |
KF16 |
1 RES |
| VFT3/KF40/HV |
ANC250, ANC300 |
3 x BNC |
KF40 |
3 Open Loop |
| VFT4/SCN/KF49/HV |
ANC350 |
4 x SCN |
KF40 |
4 Open Loop |
| VFT3/RES/KF40/HV |
ANC350 |
3 x RES |
KF40 |
3 RES |
| VFT1/NUM/KF40/HV |
ANC350 |
1 x NUM |
KF40 |
1 NUM |
| VFT3/CF40/UHV |
ANC250, ANC300 |
3 x BNC |
CF40 |
3 Open Loop |
| VFT4/SCN/CF40/UHV |
ANC350 |
4 x SCN |
CF40 |
4 Open Loop |
| VFT3/RES/CF40/UHV |
ANC350 |
3 x RES |
CF40 |
3 RES |
| VFT1/NUM/CF40/UHV |
ANC350 |
1 x NUM |
CF40 |
1 NUM |
| VFT3/NUM/KF63/HV |
ANC350 |
3 x NUM |
KF63 |
3 NUM |
| VFT3/NUM/CF63/UHV |
ANC350 |
3 x NUM |
CF63 |
3 NUM |
Fiber Feedthroughs
:.........................................................................................
solutions to feed your fibers into your cryostat
or vacuum chamber
FEED |
|
GFS230/UHV |
GFS230/UHV glass fiber
set with 3 feedthroughs
in a CF40 flange, incl. fibers,
outside and inside FC connectors, 2m length |
GFS230/HV |
GFS230/HV glass fiber
set with 4 feedthroughs
in CF 40 flange, incl. fibers,
outside and inside FC connectors, 2m length |
GFS230/LT |
GFS230/LT glass fiber
set with 4 feedthroughs
in a KF40 flange, incl. fibers,
outside and inside FC connectors, 2m length |
Request Quotation & Support : |
|
|
 |

 |
| CF63 flange with three Sub-D feedthroughs |
| |
 |
| CF40 flange with one D-Sub feedthroughs |
| |
 |
| woven flat cables, Kapton® coating, length 0.5 m |
| |
 |
| KF40 flange with one D-Sub feedthrough |
| |
 |
| K25 flange with one LT compatible 6-pin feedthrough |
| |
 |
| CF40 flange with one glass fiber feedthrough |
|